2U JBOD or flash expansion shelf
Host less expansion shelf in 2U with 24 NVMe bays over PCIe Gen5 or 24 SAS bays and dual redundant I/O modules, for growing storage without another host.
- Drives
- 24 x 2.5 inch bays, E3.S or U.2 NVMe, or SAS and SATA in the JBOD variant
- Connectivity
- NVMe: PCIe Gen5 over MCIO cables; JBOD: 4 x 24 Gb/s SAS wide ports
- Redundancy
- Dual hot swap I/O modules, dual power supplies, redundant fans
- Capacity
- Up to 737 TB raw NVMe or 368 TB SAS flash per shelf
- Daisy chain
- Multiple shelves per host, cascaded
- Power
- About 0.6 kW per shelf planning figure
Overview
An expansion shelf adds drive bays to an existing storage server without adding a second host, which keeps the storage software simple and the cost per bay low. The NVMe variant presents 24 E3.S or U.2 drives to the host over PCIe Gen5 cables, and the JBOD variant presents 24 SAS or SATA drives over 24 Gb/s SAS with cascade ports for several shelves in a chain.
It is used to grow the capacity of the 2U and 4U storage servers, to build a large flash pool behind a single pair of high availability heads, and to give a GPU server a local dataset far larger than its internal bays. Dual I/O modules, dual power supplies and redundant fans keep the shelf serviceable without downtime.
We quote the shelf with the matching host adapter, cables and drives so that it arrives as a working set. Plan for about 0.6 kW per fully populated shelf. The enclosure reports drive and environmental status to the host over SES.
Use cases
- Growing storage servers
- Large flash pools behind HA heads
- Local datasets for GPU servers
- Backup and archive expansion
Specifications
| Drive bays | 24 x 2.5 inch hot swap, E3.S or U.2 NVMe, or 24 x SAS or SATA SSD |
|---|---|
| Capacity | Up to 737 TB raw with 30.72 TB NVMe drives |
| Enclosure management | SES over the I/O modules, drive locate and fault LEDs |
| NVMe shelf | PCIe Gen5 x16 per I/O module via MCIO cables to the host or PCIe switch adapter |
|---|---|
| JBOD shelf | 4 x 24 Gb/s SAS wide ports per I/O module, cascade ports for daisy chaining |
| Host adapters | PCIe retimer or switch card for NVMe, SAS HBA for JBOD, supplied with the shelf |
| Form factor | 2U rackmount, air cooled, no CPU or memory |
|---|---|
| Power supplies | Redundant 1,200 W class PSUs, 100 to 240 V input |
| Planning power | About 0.6 kW per shelf fully populated |
| Cabling | MCIO or SAS cables to 2 m included |
Figures describe the system class. Exact configuration, weights and power draw are confirmed on the quotation.
What's included
- Rails and power cords
- Host adapter card and cables to 2 m
- Burn in with all bays populated and acceptance report
- 3 year warranty, options to 5 years
Compliance
This product is not a data center GPU system and does not require NVIDIA end user registration. Standard export documentation applies. Read about export compliance.
Compare it with the next class up or down
The nearest classes we quote are the 2U 24 bay all NVMe storage server and the 4U 36 bay HDD storage server. If neither is quite right, tell us the workload and we specify the system between them.
- (858) 613-1818
- sales@computermodules.com
- Monday to Friday, 8am to 5pm Pacific